CPL-4 · RING COUPLING BENCH

COUPLED-MODE THEORY · 4 PORTS
BOOTING
ȧ = (iΔ − κ/2)·a + √κ₁·sin  ·  sthru = sin − √κ₁·a QL –Qi –Qex – κ/2π –ER –η – τg(0) –buildup –
HELP MODE · tap any ? for a short explanation · the formulas are in EQUATIONS AND GUIDE under each tab · press ? HELP again to hide the marks
PORT SPECTRA
PHASE · GROUP DELAY
COMPLEX PLANE · PORTS
WHERE THE LIGHT GOES
EQUATIONS AND GUIDE — STEADY STATE

t = (A − iΔ)/(κ/2 − iΔ) with A = (κ₀ + κ₂ − κ₁)/2, and d = −√(κ₁κ₂)/(κ/2 − iΔ) at the drop port. On resonance Tmin = (2A/κ)², the drop peak is 4κ₁κ₂/κ², and what is left, 4κ₀κ₁/κ², is lost in the ring. Inside, the light builds up to (2/π)·η·finesse times the input.

Close the gap. Drag BUS GAP down and watch the dip: it widens all the way, but it deepens only until critical coupling (κ₁ = κ₀: every photon is lost in the ring, none comes out), then fills in again. Two different rings give the same dip, which is what the MEASURE tab is about. The phase screen tells them apart: under-coupled is a small wiggle with negative group delay, over-coupled winds through a full 2π and delays the light by τg(0) = 4κ₁/(κ₁² − κ₀²). In the complex plane t(Δ) is a circle through 1 with radius η = κ₁/κ, and it swallows the origin at the same moment.

ADD-DROP bolts on a second waveguide. From the bus it looks like extra loss, so critical coupling moves to κ₁ = κ₀ + κ₂. BACKSCATTER lets the clockwise wave leak into the counter-clockwise one: the line splits by γ, light comes back out of the input, and the zero of transmission moves to κ₁ = √((κ₀+κ₂)² + γ²). IDEALITY below 1 means the coupler itself wastes light, which caps how far you can over-couple. The span stays put while you turn knobs, so you see the line broaden; FIT SPAN re-centres the view.

PRESET SOURCES AND WHAT IS IDEALIZED

Idealized throughout: one mode family and no mode crossings · a point coupler (IDEALITY adds its loss) · one exponential gap law, anchored at an assumed critical gap · equal linewidths for pump, signal and idler · one thermal time constant with order-of-magnitude Rth and τth · no χ⁽²⁾, Raman or nonlinear loss · quantum numbers are bounds for the cavity output, before any detection loss.